Model
& Range |
PST
- 1 |
Monostats ( -500 to + 1000Pa ) |
PST - 2 |
Monostats ( -500 to +1000mmH2O
) |
PST - 3 |
Monostats ( -250 to +500mbar
) |
PST - 4 |
Monostats ( -1000 to 2000mbar ) |
 |
Specifications |
Á¤È®µµ
|
PST - 1 : ¡¾2% of reading ¡¾3Pa |
| PST - 2 : ¡¾2% of reading ¡¾3mmH2O |
| PST - 3 : ¡¾2% of reading ¡¾3mbar
|
| PST - 4 : ¡¾2% of reading ¡¾3mbar
|
Àü¿ø |
24Vac/Vdc |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Refrigeration and air-conditioning |
ABS
housing - IP 65
Display 5-digit LCD
1 RCR relay 3A/230Vca
red LED in front
Software or DIP switch configuration
Autozero manual with push-button
Quick and easy mounting with the ¨ù turn system
with wall-mount plate
|
|
|
 |
|
|
Model
& Range |
CP
50
|
Class 50 ( -5000 to 10000Pa ) |
|
Specifications |
Á¤È®µµ
|
¡¾2% of reading ¡¾3mmH2O |
Àü¿ø |
24Vac/Vdc |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Refrigeration, building services,
indoor climate, original equipment, manufacturer |
Configurable
intermediary and central zero ranges
ABS housing - IP 65
Software or DIP switch configuration
Autozero manual with push-button
mounting with the ¨ù turn system with wall-mount
plate
|
|
| |
 |
| |
Model
& Range |
CP
101 |
Class 100 ( -500 to +1000Pa ) |
CP 102 |
Class 100 ( -500 to +1000mmH2O
) |
CP 103 |
Class 100 ( -250 to +500mbar
) |
CP 104 |
Class 100 ( -1000 to + 2000mbar ) |
|
Specifications |
Á¤È®µµ
|
CP 101 : ¡¾1.5% of reading
¡¾3Pa |
| CP 102 : ¡¾1.5% of reading
¡¾3mmH2O |
| CP 103 : ¡¾1.5% of reading
¡¾3mbar |
| CP 104 : ¡¾1.5% of reading
¡¾3mbar |
Àü¿ø |
24Vac/Vdc |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Refrigeration, air-conditioning,
industries, OEM |
Configurable
intermediary and central zero ranges
ABS housing - IP 65
Display : with or without 5-digits LCD
Software or DIP switch configuration
Autozero manual with push-button
mounting with the ¨ù turn system with wall-mount
plate
|
|
| |
 |
| |
Model
& Range |
CP
201 |
Class 200 ( -1000 to +1000Pa ) |
CP 202 |
Class 200 ( -10000 to +10000Pa
)
|
CP 203 |
Class 200 ( -500 to +500mbar
) |
CP 204 |
Class 200 ( -2000 to + 2000mbar ) |
 |
Specifications |
Á¤È®µµ
|
CP 201 : ¡¾1% of reading ¡¾2Pa |
| CP 202 : ¡¾1% of reading ¡¾2Pa |
| CP 203 : ¡¾1% of reading ¡¾2mbar
|
| CP 204 : ¡¾1% of reading ¡¾2mbar
|
Àü¿ø |
24Vac/Vdc, 115Vac or 230Vac |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Industries, pharmaceutical
plants |
Configurable
intermediary and central zero ranges
Air velocity and airflow functions (
optional )
Simultaneous display of 2 parameters
2 output 4-20mA or 0-10V ( 4 wires ),
RS 232, 2RCR relays 6A/230Vac
2 visual ( dual color LED ) and audible
( buzzer ) alarms
Software or keypad
configuration
ABS - IP 65 housing, with or
without 2-line backlit display
mounting with the ¨ù turn system with wall-mount
plate
|
|
| |
 |
| |
Model
& Range |
CP
301 |
Class 300 ( -100 to +100Pa ) |
CP 302 |
Class 300 ( -500 to +500Pa
)
|
CP 303 |
Class 300 ( -1000 to +1000Pa
) |
CP 304 |
Class 300 ( -10000 to +10000Pa ) |
 |
Specifications |
Á¤È®µµ
|
¡¾0.5% of reading ¡¾1Pa |
Àü¿ø |
24Vac/Vdc, 115Vac or 230Vac |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Industries, pharmaceutical
plants |
Configurable
intermediary and central zero ranges
Air velocity and airflow functions (
optional )
Interchangeable measuring sensor
( SPI technology )
Simultaneous display of 1 to 4 parameters
External transmitter unputs
( KIMO class 200 and 300 ) and thermocouple
K
2 output 4-20mA or 0-10V ( 4 wires ),
RS 232, 2RCR relays 6A/230Vac
2 visual ( dual color LED )
and audible ( buzzer ) alarms
Software, keypad or remote control
configuration
MODBUS network RS 485 system
( optional )
ABS or ALU IP 65 housing, with
or without backlit gaphic display
mounting with the ¨ù turn system with wall-mount
plate
|
|
| |
 |
|
|
Model
& Range |
CPE
301 |
Class 300 ( -100 to +100Pa ) |
CPE 302 |
Class 300 ( -500 to +500Pa
)
|
CPE 303 |
Class 300 ( -1000 to +1000Pa) |
 |
Specifications |
Á¤È®µµ
|
¡¾0.5% of reading ¡¾1Pa |
Àü¿ø |
24Vac/Vdc |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Industries, pharmaceutical
plants |
Configurable
intermediary and central zero ranges
Face Calibration
Interchangeable measuring sensor (
SPI technology )
Alternating display of 1
to 3 parameters
External transmitter unputs
( KIMO class 200 and 300 )
2 output 4-20mA or 0-10V ( 4 wires ),
RS 232, 2RCR relays 6A/230Vac
2 visual ( dual color LED )
and audible ( buzzer ) alarms
Remote control configuration
MODBUS network RS 485 system
( optional )
Front made of brushed stainless steel
or white lacquered, with electroluminescent
display
|
|
| |
 |
| |
Model
& Range |
CPA
301 |
Class 300 ( -100 to +100Pa ) |
CPA 302 |
Class 300 ( -500 to +500Pa
)
|
CPA 303 |
Class 300 ( -1000 to +1000Pa
) |
CPA 304 |
Class 300 ( -10000 to +10000Pa) |
 |
Specifications |
Á¤È®µµ
|
CPA 301, 302, 303 : ¡¾0.5%
of reading ¡¾1Pa |
| CPA 304 : ¡¾0.5% of reading
¡¾10Pa |
Àü¿ø |
24Vac/Vdc, 115Vac or 230Vac |
À¯Ã¼Á¾·ù |
°ø±â, Áß¼º°¡½º |
Application |
Industries, pharmaceutical
plants |
Configurable
intermediary and central zero ranges
Air velocity and airflow functions
( optional )
Interchangeable measuring sensor
( SPI technology )
Simultaneous display of 1 to 4 parameters
External transmitter unputs
( KIMO class 200 and 300 )
2 output 4-20mA or 0-10V ( 4 wires ),
RS 232, 2RCR relays 6A/230Vac
Audible alarms ( buzzer - 80 dB )
Output dianostics
MODBUS network RS 485 system
( optional )
Multi-directional housing made of ABS
Large display 50 * 190 mm
|
|