Model & Range
KH100
Class 100

3 internal measurements
Range
Resolution
Humidity
5 to 95%HR 0.1%HR
Temperature
-20 to +70”ĘC 0.1”ĘC
Sensing element
Varistor / digital capacitive
Light
0 to 10000 Lux 1 Lux
Sensing element
Photodiode
Housing
Working temperature
-20 to +70”ĘC
Protection
IP 40
Humidity, temperature and light datalogger
* Measure up to 3 parameters
* Internal sensing element
* Up to 12,000 measurement points
* With or without 1-line display
* 2 configurable setpoint alarms
* Magnetic mounting
Model & Range
KT100 A
Class100
KT100 I
Class100

1 internal measurement
Range
Resolution
Temperature
-40 to +70”ĘC 0.1”ĘC
Sensing element
CTN
1 input for external probe ( KT100 A)
Range
Resolution
Temperature
-40 to +120”ĘC 0.1”ĘC
Courent
0/4 to 20mA 0.001mA
Voltage
0 to 10V 0.001V
Ammeter clamps
0 to 600A 0.1A
Housing
Working temperature
-40 to +70”ĘC
Protection
IP 40 (KT100 A), IP 67 (KT100 I)
Temperature datalogger
* Measure up to 2 parameters
* With or without external input
* Internal sensing element
* Up to 12,000 points measurement point
* With or without 1-line display
* 2 configurable setpoint alarms
* Magnetic mounting
 
Model & Range
KT200 A
Class200
KT200 I
Class200

1 internal measurement
Range
Resolution
Temperature
-40 to +70”ĘC 0.1”ĘC
Sensing element
CTN
4 input for external probe
Range
Resolution
Temperature
-40 to +120”ĘC 0.1”ĘC
Courent
0/4 to 20mA 0.001mA
Voltage
0 to 10V 0.001V
Ammeter clamps
0 to 600A 0.1A
Housing
Working temperature
-40 to +70”ĘC
Protection
IP 40 (KT200 A), IP 67 (KT200 I)
Temperature datalogger
* Measure from 1 to 5 parameters
* 4 external input
* Internal sensing element
* Up to 16,000 measurement points
* With or without 2-line display
* 2 configurable setpoint alarms
* Magnetic mounting
 
Model & Range
KH200 A
Class 200
KH200 D
Class 200

3 internal measurement
Range
Resolution
Humidity (KH200 A)
5 to 95%HR 0.1%HR
Temperature (KH200 A)
-20 to +70”ĘC 0.1”ĘC
Sensing element (KH200 A)
Varistor / Digital capacitive
Light
0 to 10000Lux 1Lux
Sensing element
Photodiode
4 input for external probe
Range
Resolution
Humidity (KH200 D)
5 to 95%HR 0.1%HR
Temperature (KH200 A)
-20 to +80”ĘC 0.1”ĘC
Sensing element (KH200 A)
Varistor/Digital capacitive
Probe (KH200 A)
ABS remote probe
Temperature
-40 to +120”ĘC 0.1”ĘC
Courent
0/4 to 20mA 0.001mA
Voltage
0 to 10V 0.001V
Ammeter clamps
0 to 600A 0.1A
Housing
Working temperature
-20 to +70”ĘC
Protection
IP 67
Humidity, temperature and light datalogger
* Measure from 1 to 5 parameters
* From 2 to 4 external inputs
* Internal sensing element
* Up to 16,000 measurement points
* With or without 2-line display
* 2 configurable setpoints alarms
* Magnetic mounting
 
Model & Range
KTR300
Class 300

2 input for external probe
Range
Resolution
Temperature
-100 to +400”ĘC 0.1”ĘC
Sensing element
Pt100 probe (optional)
Courent
0/4 to 20mA 0.001mA
Voltage
0 to 10V 0.001V
Ammeter clamps
0 to 600A 0.1A
Housing
Working temperature
-20 to +70”ĘC
Protection
IP 67
Pt 100 temperature datalogger
* Up to 2 parameters
* Thermometer function
* 2 external inputs
* Up to 100,000 points measurement point
* With 2-line display
* 2 configurable setpoint alarm
* Magnetic mounting
 
Model & Range
KTT300
Class 300

2 inputs for external probes
Range
Resolution
Thermocouple K
-200 to +1000”ĘC 0.1”ĘC
Thermocouple J
-100 to +750”ĘC
0.1”ĘC
Thermocouple T
-200 to +400”ĘC 0.1”ĘC
Sensing element
Thermocouple probe (optional)
Housing
Working temperature
-20 to +70”ĘC
Protection
IP 43
Thermocouple temperature datalogger
* Measure up to 2 parameters
* Thermometer function
* 2 external inputs
* Up to 100,000 points measurement point
* With 2-line display
* 2 configurable setpoint alarm
* Magnetic mounting
 
Model & Range
KTH300 A
Class 300
KTH300 P
Class 300
KTH300 I
Class 300

2 internal measurements ( KTH300 A )
Range
Resolution
Humidity
0 to 100%HR 0.1%HR
Sensing element
Capacitive
Temperature
-20 to +70”ĘC 0.1”ĘC
Sensing element
Pt 100
Probe
Polycarbonate (PC) ambient
2 input for external probe
Range
Resolution
Humidity (KTH300 P,I)
0 to 100%HR 0.1%HR
Sensing element (KTH300 P,I)
Capacitive
Temperature (KTH300 P,I)
(-20 to +120”ĘC, -40 to 180”ĘC) 0.1”ĘC
Sensing element (KTH300 P,I)
Pt 100
Probe (KTH300 P,I)
PC remote probe, ST.STEEL remote probe
Temperature Pt100
-100 to +400”ĘC 0.1”ĘC
Courent
1/4 to 20mA 0.001mA
Voltage
0 to 10V 0.001V
Ammeter clamps
0 to 600A 0.1A
Housing
Working temperature
-20 to +70”ĘC
Protection
IP 54 (KTH300 A), IP 67 (KTH300 P,I)
Temperature and humidity datalogger Z
* Up to 3 parameters
* Thermometer and thermo-hygrometer functions
* 1 or 2 external inputs
* Up to 100,000 measurement points
* With 2-line display
* 2 configurables setpoint alarms
* Magnetic mounting